Repository navigation
Conversation
Owner
Author
|
D27 historical stack reconciled with integrated RC. Exact ancestry: |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
M2.17-F — in-place GOOSE inspection, exact wire values, model-safe late binding
Base: stacked draft #610 at exact
e110c63f962b0a113a7c2bb543c0e7d4fd28ed15. Do not merge to main or repin ARIEC/native bridge.Physical BCUGE reproduction supplied by operator
reference IEC client shows two distinct GoCBs: LLN0.BCU publishes LLN0.GOOSE1 with its own GoID/APPID; LLN0.BCU03GE publishes LLN0.GOOSE2 with another identity. The ARSAS Browser selected LLN0.BCU, has accepted MMS GoEna/ndsCom, and shows "No uniquely verified matching frame / No exact DataSet directory" although the shared subscriber can receive frames. Browser Subscribe incorrectly navigates to GOOSE Sniff. Do not conflate BCU with BCU03GE or promote a raw GOOSE value as an MMS Read/Report observation.
Main fixes
RefreshGooseAdapters, exactResolveGooseAdapterForIed,StartGooseSubscriber_ClickandStopGooseSubscriberAsync; no second network path or decoder. Unresolved adapter selection remains explicit in Browser and never auto-chooses a lone unrelated NIC. IED-card quick-start and direct GOOSE Sniff workflows stay untouched.unboundwith real received rendered wire values and no fabricated signal names, FCs, q/t or LiveValues insertion. Rows update in place on existing UI coalescing tick; no polling, tree rebuild or shadow cache.Not current, not seemingly live stale data.Not claimed
No report on physical acceptance of this new build yet; CI is not an IEC 61850 hardware proof. Screenshot data from the previous artifact is the evidence driving this patch. Verify specifically whether the exact BCU vs BCU03GE GoCbRef is emitted and whether corresponding datSet references are discoverable. Keep source/engine pin unchanged and PR draft; BCUGE field follow-up is separate.