The predictive low alarm for Loop reads Loop's full uploaded forecast, up to 60 minutes ahead, independent of Hours of Prediction under Graph Settings, the same way it already works for Trio. The Download Prediction setting is removed, so the Loop forecast line, min/max and the alarm are always available.

Fixes #731. LF Hub gets the matching change in loopandlearn/lfhub, and #796 needs storage.downloadPrediction dropped from HubClient's client settings once this is in dev.

@marionbarker marionbarker left a comment

Copy link
Copy Markdown
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Approve by code review and test.