lovkeshsharma702
left a comment
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
please change the doc to below. rest all looks good to me.
RCA:
After upgrading the leaf to an affected version, interface configurations are not pushed because the "pres.Listener" object is missing in the APIC.
This occurs due to an incomplete/faulty APIC upgrade.
IMPACT:
If "pres.Listener" is missing after a leaf upgrade or clean reload, leaf ports remain out of service, and infraAccPortP and infraAccBndlGrp cannot program interfaces.
Suggestion:
Verify that all active leaf node objects are present in the "pres.Listener" list (class 4307) and alert if the affected version is detected. If an alert is raised, upgrade to a version that includes the fix for [CSCwn81692][62].
lovkeshsharma702
left a comment
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Script been tested and validate the serious bug
…ade-Validation-Script into muthuku-CSCwn81692
Added validation for CFD CSCwn81692