Skip to content

web: read a failed board sensor as a sensor fault in the health block - #57

Merged
aq1018 merged 1 commit into
mainfrom
web-sensor-fault
Nov 14, 2026
Merged

aq1018 merged 1 commit into
mainfrom
web-sensor-fault

Conversation

@aq1018

@aq1018 aq1018 commented Nov 14, 2026

Copy link
Copy Markdown
Contributor
  • With therm_flags NTC_FAULT set the Winding row shows a "sensor fault" badge in place of 327.7 C, and the stale board temperature is hidden; the cutoff line stays.
  • Unit tests on the flag. No browser spec: the simulated servo's winding stand-in never raises NTC_FAULT, so the spec waits on that (a firmware repo change).

@aq1018
aq1018 merged commit af0b06c into main Nov 14, 2026
1 check passed