Variable-resolution gravity-wave absorbing layer formulation change #1379
+3
−8
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
This PR removes the scaling of the gravity-wave absorbing layer coefficient by the local mesh size. Previously, the absorbing layer coefficient was scaled by dx/dx_fine. For large values of dx/dx_fine instabilities have been ancountered associated with this scaling of the absorbing layer coefficient.
Units have been added to the configuration variable config_xnutr (1/s) in the Registry - it is used in calculating the absorbing layer coefficient. Units have also been added to config_visc4_2dsmag (m/s) in the Registry - it is used in the calculation of the hyperviscosity.