Set the EMCAL sampling factor for the G4HepEm physics list
This makes the Geant4 sampling factor for FTFP_BERT_EMV_HEP+optical explicit.
- The value 0.808 gives the same EMCAL energy per primary as FTFP_BERT_EMV+optical with 0.821.
- It was determined with e- of 1 to 20 GeV and gamma of 1 to 5 GeV; the agreement is within 1 % at all energies.
- Before, the list fell back to the default 0.81 by name.
https://its.cern.ch/jira/browse/O2-7210
https://its.cern.ch/jira/browse/O2-7316