STM32: SPI 3 wires mode not supported in SPI slave
This patch handles the case of SPI slave mode without MISO (NC).
In case MISO is not connected, we consider that SPI will be configured in
3 wires mode (CLK / MOSI / CS, but no MISO). In this case, the MOSI line
is bi-directional : SPI_DIRECTION_1LINE.
But as this is not supported yet in slave mode, we force it to
SPI_DIRECTION_2LINES. In this case slave SPI will receive data on MOSI
but nothing will be sent back to master as MISO is not connected.1 parent 1f47dab commit 1c67d62